Sun StorEdge 9910 Data System Support Expertise

Independent Sun StorEdge 9910 Data System Support Expertise



Sun StorEdge 9910 Data SystemCombines a revolutionary switched architecture with sophisticated RAS features to provide truly non-disruptive performance and availability for mission-critical data services. Complements Sun's scalable line of Sun StorEdge[tm] T3 arrays. Full spectrum of leading-edge storage software. Prompt worldwide support from mission-critical service centers.

Capacity And Performance

  • Maximum usable capacity for RAID 1+ Open systems S/390 compatible : 1.6 TB, 1.5 TB
  • Total raw capacity per subsystem : 3.5 TB
  • Maximum usable capacity for RAID 5 Open systems S/390 compatible : 2.4 TB, 2.3 TB
  • Capacity (GB) 3" form factor, 10K RPM : 18, 72
  • Hot spares (maximum) : 4
  • Number of disk drives (with spares) : 5 to 48
  • Heat : 3.3 kW
  • Power : 3.1 kVA
 

Standard Interfaces

  • Logical Device Support : Up to 4,096
  • Control Memory : Up to 1.5 GB
  • Data Cache Increments : 1 GB
  • Data Cache Minimum : 1 GB
  • Data Cache Maximum : 16 GB
 

Interfaces

  • Number of CHIP pairs : Up to 3
  • Simultaneous data transfers per CHIP pair : 4 or 8
  • Physical interfaces per CHIP pair : 4 or 8
  • Maximum : 24
  • Fibre Channel (fiber-optic cable) : 0, 4, 8, 12, 16, 20, or 24
  • Extended Serial Adapters (compatible with ESCON protocol) : 0, 4, 8, 12, 16, 20, or 24
 

Array Control Processor

  • Number of ACP pairs per subsystem : 1
  • Physical array paths per ACP pair : 8
  • Maximum disks per array path : 12
  • Simultaneous transfers per ACP pair To cache : 4
  • Simultaneous transfers per ACP pair To disk array : 8
  • Transfer rate Per disk array path : Up to 100 MB/sec
  • Transfer rate Per ACP pair (to cache) : Up to 800 MB/sec
  • Transfer rate Per fully configured system : 3.2 GB/sec
 

Dimensions And Weight

  • Height : 1,790mm (70.5 in.)
  • Width (with two side panels) : 700mm (27.6 in.)
  • Depth : 800mm (31.5 in.)
  • Weight : 524 kg (1,153 lbs.)