Sun StorEdge 6910 and 6960 data Systems Support Expertise

Independent Sun StorEdge 6910 and 6960 data Systems Support Expertise



Sun StorEdge 6910 and 6960 data SystemsThe Sun StorEdge 6900 series is the ideal system for providing low cost SAN attach multi-platform storage, simplifying high performance clustering. The StorEdge 6900 series arrays have also been optimised for clustering and is based on the Sun StorEdge T3 Enterprise array.
The Sun StorEdge 6900 series is available in two configurations. The StorEdge 6910 is available with a minimum of one Enterprise T3 array (2 trays), and can be configured to a maximum of three Enterprise T3 arrays (6 trays). The StorEdge 6960 is available with a minimum of one Enterprise T3 array (2 trays) and can be configured with a maximum of eight Enterprise T3 arrays (16 trays).
The StorEdge 6900 series has an integrated Virtualisation Engine (VE) which modifies the partitioning of physical disk drives with fixed storage capacities into virtual disks which can rapidly be redefined as application needs change. VE's are installed in pairs to ensure redundancy and high availability. This allows each pair of VE's to provide physical access to all aspects of the storage arrays with multiple I/O paths to individual arrays.
The StorEdge 6900 series arrays include two SAN fibre switches and a 72" cabinet.

Sun Storedge 6960

  • 655 to over 10.6Tb with the addition of an Expansion Cabinet
  • 36Gb 10Krpm or 73Gb 10Krpm drives
  • 2Gb to 16Gb mirrored battery-backed cache (1-8Gb usable)
  • No single point of failure: all components are hot swappable/redundant
  • Redundant high availability hardware RAID 5 and RAID 1+0
  • Solaris 8, Windows NT and Windows 2000
  • Supports up to fourteen hosts
  • Supports up to 512LUNs
  • Sun Cluster 3.0 and VERITAS Cluaster server 2.0 certified and supported
  • Sun two year enhanced warranty
  • Sun StorEdge Remote Response service ready
 

Sun Storedge 6910

  • 655Gb to over 4TB in a single cabinet
  • 36Gb 10Krpm or 73Gb 10Krpm drives
  • 2Gb to 6Gb mirrored battery-backed cache (1-3Gb usable)
  • No single point of failure: all components are hot swappable/redundant
  • Redundant high availability hardware RAID 5 and RAID 1+0
  • Solaris 8, Windows NT and Windows 2000
  • Supports up to seven hosts
  • Supports up to 256 LUNs
  • Sun Cluster 3.0 and VERITAS Cluaster server 2.0 certified and supported
  • Sun two year enhanced warranty
  • Sun StorEdge Remote Response service ready